GAUGE FACE CORNER DEFECTS ULTRASONIC RAIL TESTER

  • Light weight, portable & robust in construction rail tester.
  • Capable to detect gauge face corner flaws, other transverse flaws and piping defects in rail head. Discontinuity in welded joints in rail head and any horizontal defects in rail head.
  • Capable of operating both in single & double crystal mode simultaneously or independently.
  • Provided 0? , 70? (F&B) 45? probe with special gadgets.
  • Easy to operate , application and handle.
  • Reliable in good workmanship and trouble free performance.
  • UFD capable of swiveling by horizontally and vertically for easy viewing by operator.
  • Having 99 sets of calibration memory.
  • Setting of all parameters can be locked .
  • Complete rail tester can be accommodated in a carrying box.
  • Training on operation of equipment and testing technique will be in parted by firm while supply the of equipments.
 
TECHNICAL DATA

Frequency Range: 0.5 to 15 MHz by wide band amplifier.

Test Range: 0-50mm min., 0-500mm Max., 2 step coarse selection and continuous variable fine selection.

Linearity: Horizontal - 1% / Vertical - 5%

Sensitivity: Variable in 1dB step from 0to 99 dB

Suppression: Linear type. Continuous variable between 0 to 100% full screen height. Visual indication when active.

Pulse Damping: Selectable values 1K?, 150?, 100? & 47?
                            LED indication of selected value.

Monitor: Gate start, Gate Width controllable between 1 div. To full screen width & gate threshold variable between 10 to 100% full screen height. Audio & Visual Alarm, Gate Search & OFF selection. Audio alarm mute available.

CRT: 70 x 55 mm screen with internal graticule. Bright display, free from distortion & parallax error. 10 x10 main divisions, each with small sub-divisions.

Digital Display: 2 digit 7 segment LED to display to indicate –
                              a) Gate threshold, suppression in 1 to 10 steps corresponding approximately to 10 to 100 % F.S.H.
                              b) Gain in dB, in 1 dB step.
                              c) Memory set no. 1 to 99.

Pulse Delay: Range dependent, min.200mm & max.3 m on 250mm & 1 m range

Keyboard: Functional sealed touch control for all parameters.
                  Visual indication of selected parameter.
                  “Smart Knob” for function value change, to get the analogue feel.

Calibration Memory: 99 sets. All parameters can be stored in memory.

Lock: Setting for all parameters can be locked.

Test Method: Pulse Reflection or Pulse Transmission.

Operating Modes: Single Probe, Double Probe, T-R Mode.

Power Supply: Plug-in battery pack type BAT 10 with rechargeable dry cells providing up to 3 hours continuous operation.

Battery Check: By flash LED indicator.

Drift: Sweep: Less than 0.7mm/10°C. Vertical: Less than 0.3dB/10°C.

Temperature Range: Up to 55°C.

Recorder: Output suitable to record ‘A-Scan’ trace pattern & instrument parameters.
                  Optional items, recorders & software to download data to P.C. for storage of test data and report printing.

Weight (Approx.): With battery pack - 4.5 Kg.

Size (Approx.): 220(W) x 95(H) x 330 (L) mm

 
   
       